![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/4f/24ff5093-154a-4e1c-ac41-c0054224feca/24ff5093-154a-4e1c-ac41-c0054224feca-bg20.png)
Black 0032
Black0032
AUTOMATION OUTPUT WHILE ARMED
◆
The factory setting causes the Console’s
Automation Output to activate when pressing
the [
(A)
] key, or when it’s triggered with a
two-button remote control.
◆
In addition, the Console can be programmed to
activate the Automation Output when the system
is armed.
AUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS
◆
The factory setting causes the Console’s
Automation Output to activate when pressing
the [
(A)
] key, or when it’s triggered with a
two-button remote control.
◆
In addition, the Console can be programmed to
activate the Automation Output during the exit
and Entry Delays.
AUTOMATION OUTPUT POLARITY
◆
The factory setting causes the Console’s
Automation Output to provide a current limited
voltage source when activated.
◆
Alternately, the Console can be programmed so
the Automation Output provides a current
limited voltage source when
deactivated
.
REMOTE ACCESS PASSWORD
◆
This is the password used to gain access to the
Console when using the RA-2400 remote access
software.
◆
The password must be 6-digits long.
Log the remote access password in the box below.
REMOTE ACCESS PASSWORD
DURESS CODE
◆
The duress code will disarm the system, without
any special indications or sounds, but will send the
programmed duress code to the Central Station.
◆
The duress code should be
two or more digits
different than any user code.
Log the duress code in the box below.
DURESS CODE
MASTER USER CODE
◆
The master user code is 1234 when power is first
applied to the Console.
◆
The master user code can be changed through
programming to any 1-5 digit code. Only the
master user can access Setup Mode, restricted
users cannot.
✍
NOTE: For maximum security, a 3-5 digit code is
recommended.
Log the master user code in the box below.
MASTER USER CODE
7
PRS
3
DEF
HOME
AWAY
PROGRAMMING STEP #73
PROGRAM
STORE PROGRAM
0 FOR STANDARD TRIGGER
1 FOR OUTPUT WHEN ARMED
7
PRS
4
GHI
HOME
AWAY
PROGRAMMING STEP #74
PROGRAM
STORE PROGRAM
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING
EXIT/ENTRY DELAYS
7
PRS
5
JKL
HOME
AWAY
PROGRAMMING STEP #75
PROGRAM
STORE PROGRAM
0 FOR VOLTAGE WHEN OFF
1 FOR VOLTAGE WHEN ON
8
TUV
7
PRS
HOME
AWAY
PROGRAMMING STEP #87
PROGRAM
STORE PROGRAM
6-DIGIT REMOTE
ACCESS PASSWORD
9
WXY
9
WXY
HOME
AWAY
PROGRAMMING STEP #99
PROGRAM
STORE PROGRAM
1-5 DIGIT MASTER CODE
(3-5 DIGITS RECOMMENDED)
9
WXY
2
ABC
HOME
AWAY
PROGRAMMING STEP #92
PROGRAM
STORE PROGRAM
1-5 DIGIT DURESS CODE
(3-5 DIGITS RECOMMENDED)