COMMUNICATOR REPORTING CODES
◆
The two-digit communicator reporting code for
each event has a factory set value. These values
may be customized to fit the specific installation
and the reporting requirements of the Central
Station monitoring the system.
◆
If Point ID reporting is enabled (the factory
default setting), each sensor can report a unique
alarm and trouble code.
◆
If Point ID is disabled, the “general” reporting
codes for each event type will be used.
◆
Each programming function is performed with
similar keystrokes. After the Console is in Setup
Mode, enter the programming step number,
press the [
HOME
] key (HOME = program), enter
the new value, and press the [
AWAY
] key
(AWAY = store).
◆
Making a value 0 causes event to not
communicate to central station.
✍
NOTE: The reporting codes are fixed for opening
and closing. A unique code is reserved for the
master and the five restricted user codes. See the
Opening & Closing Reporting Codes Table.
GENERAL REPORTING CODES
◆
Program Steps #201 - 206 for the communicator
reporting codes when Point ID is disabled.
◆
Refer to the Console & General Reporting Codes
table to view/edit the reporting codes for each of
the five events. The factory settings are listed,
along with a blank area to write in the new
installation values.
◆
Any value from 0-99 can be programmed for
each event (0 = no report).
✍
NOTE: Be careful not to duplicate codes unless
the Central Station requires specific codes for
certain types of events.
SYSTEM REPORTING CODES
◆
Program Steps #261 - 266 for the Console
reporting codes.
◆
Refer to the System Reporting Codes table to
view/edit the reporting codes for the keypad
[FIRE]
and
[EMERGENCY]
buttons and for each of the
four Control Panel conditions. The factory settings
are listed, along with a blank area to write in the
new installation values.
GENERAL REPORTING CODES
STEP #
PROGRAMMING
FUNCTION
POSSIBLE
VALUES
FACTORY
VALUE
INSTALLATION
VALUE
201 GENERAL FIRE REPORT CODE 0 - 99 1
202 GENERAL EMERGENCY REPORT CODE 0 - 99 2
203 GENERAL SILENT PANIC REPORT CODE 0 - 99 3
204 GENERAL BURGLARY REPORT CODE 0 - 99 4
206 GENERAL TROUBLE REPORT CODE 0 - 99 6
General Reporting Codes Table
HOME
TEST
= PROGRAM
= REMOVE
AWAY
= STORE
0
HOME
AWAY
0 - 99 FOR GENERAL
ALARM REPORTING CODE
PROGRAMMING STEPS
#201 TO #206
PROGRAM
STORE PROGRAM
2
ABC
6
MNO
HOME
AWAY
0 - 99 FOR SYSTEM
REPORTING CODE
PROGRAMMING STEPS
#261 TO #266
PROGRAM
STORE PROGRAM
2
ABC
38