A SERVICE OF

logo

Final Charge
Final Charge
The final step in the analysis process is to recharge the battery pack after it is fully discharged. The final charge requires about
2.5 hours.
The LCD indicates:
l The battery is discharging, indicated by the word DISCHARGE on the screen.
l This is the second (and final) charge cycle, indicated by the number 2 on the screen.
l The battery is under analysis, indicated by the word ANALYZE on the screen.
l The battery capacity measured during the analysis (1310mAh). This is an example and can vary depending on the bat-
tery pack’s maximum capacity.
Ready
The Ready indicator is displayed at the end of the analyze process.
The LCD indicates:
l The battery was under analysis, indicated by the word ANALYZE on the screen.
l The process is complete and the battery is ready for use, indicated by the word READY on the screen.
l The battery capacity as it is measured during the analysis (1400mAh).
l The battery voltage after charge (12.2VDC). This can vary from 12.0VDC to 12.7VDC.
Battery Fault
On rare occasions, the charge or analysis process may fail. If this occurs, note the information on the LCD screen. Contact
your LXE representative if the problem cannot be resolved from the information in the “Troubleshooting” section.
The LCD indicates:
l The process when the fault occurred. For example, if the fault occurred during the discharge cycle of the analyze proc-
ess, words (DISCHARGE; 1; ANALYZE) are displayed on the screen.
l A battery fault has occurred, indicated by the words BAT. FAULT on the screen.
l The current battery voltage.
l An error code indicating the nature of the fault (for example, E04Contact your LXE representative for more information
on the error code.