157
Parameter List
Appendices
29: DISTORTION→CHORUS (p. 104)
The parameters are essentially the same as "26: OVERDRIVE →CHORUS,"
with the exception of the following two.
OD Drive→Dist Drive, OD Pan→Dist Pan
30: DISTORTION→FLANGER (p. 105)
The parameters are essentially the same as "27: OVERDRIVE →FLANGER,"
with the exception of the following two.
OD Drive→Dist Drive, OD Pan→Dist Pan
31: DISTORTION→DELAY (p. 105)
The parameters are essentially the same as "28: OVERDRIVE →DELAY," with
the exception of the following two.
OD Drive→Dist Drive, OD Pan→Dist Pan
32: ENHANSER→CHORUS (p. 105)
Parameter Value
Enhancer Sens Enhancer sens 0–127
Enhancer Mix Enhancer mix level 0–127
Cho Dly Chorus pre delay time 0.0–100.0 ms
ChoRate Chorus rate 0.05–10.00 Hz
Chorus Depth Chorus depth 0–127
Chorus Balance Chorus balance D100:0W–D0:100W
Level Output level 0–127
33: ENHANSER→FLANGER (p. 105)
Parameter Value
Enhancer Sens Enhancer sens 0–127
Enhancer Mix Enhancer mix level 0–127
Flg Dly Flanger pre delay time 0.0–100.0 ms
FlgRate Flanger rate 0.05–10.00 Hz
Flg Dpt Flanger depth 0–127
Flg Fbk Flanger feedback level -98–+98%
Flanger Balance Flanger balance D100:0W–D0:100W
Level Output level 0–127
34: ENHANSER→DELAY (p. 106)
Parameter Value
Enhancer Sens Enhancer sens 0–127
Enhancer Mix Enhancer mix level 0–127
Delay Delay time 0.0–500.0 ms
Dly Fb Delay feedback level -98–+98%
Delay HF Damp Delay HF damp 200–8000 Hz,
BYPASS (*1)
Delay Balance Delay balance D100:0W–D0:100W
Level Output level 0–127
*1: 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150,
4000, 5000, 6300, 8000 Hz, BYPASS
35: CHORUS→DELAY (p. 106)
Parameter Value
Cho Dly Chorus pre delay time 0.0–100.0 ms
ChoRate Chorus rate 0.05–10.00 Hz
Cho Dpt Chorus depth 0–127
Cho Bal Chorus balance D100:0W–D0:100W
DlyTime Delay time 0.0–500.0 ms
Dly Fbk Delay Feedback level -98–+98%
Delay HF Damp Delay HF damp 200–8000 Hz,
BYPASS (*1)
Delay Balance Delay balance D100:0W–D0:100W
Level Output level 0–127
*1: 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150,
4000, 5000, 6300, 8000 Hz, BYPASS
36: FLANGER→DELAY (p. 106)
Parameter Value
Flg Dly Flanger pre delay time 0.0–100.0 ms
FlgRate Flanger rate 0.05–10.00 Hz
Flg Dpt Flanger depth 0–127
Flg Fbk Flanger feedback level -98–+98%
Flg Bal Flanger balance D100:0W–D0:100W
DlyTime Delay time 0.0–500.0 ms
Dly Fbk Delay feedback level -98–+98%
HF Damp HF damp 200–8000 Hz,
BYPASS (*1)
Delay Balance Delay balance D100:0W–D0:100W
Level Output level 0–127
*1: 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150,
4000, 5000, 6300, 8000 Hz, BYPASS
37: CHORUS→FLANGER (p. 107)
Parameter Value
Cho Dly Chorus pre delay time 0.0–100.0 ms
ChoRate Chorus rate 0.05–10.00 Hz
Cho Dpt Chorus depth 0–127
Cho Bal Chorus balance D100:0W–D0:100W
Flg Dly Flanger pre delay time 0.0–100.0 ms
FlgRate Flanger rate 0.05–10.00 Hz
Flg Dpt Flanger depth 0–127
Flg Fbk Flanger feedback level -98–+98%
Flanger Balance Flanger balance D100:0W–D0:100W
Level Output level 0–127
38: CHORUS/DELAY (p. 107)
Refer to “35: CHORUS→DELAY.”
39: FLANGER/DELAY (p. 107)
Refer to “36: FLANGER→DELAY.”
40: CHORUS/FLANGER (p. 107)
Refer to “37: CHORUS→FLANGER.”