The DSR 700 has been designed for use in large multi-channel systems. To find intermodulation-
free and clean carrier frequencies quickly and easily, we recommend using the QUICK SETUP func-
tion to find all required channels.
1. To start QUICK SETUP, select the START SETUP menu, set the required number of channels as
well as the required frequency ranges and start scanning.
The scan procedure can take up to one minute. The CHANNEL LIST shows you clean channels
in a user-friendly list.
2. To assign and synchronize a clean channel to the receiver you can use the channel button.
3. Use the CONTINUE SCAN sub-menu to search for other frequencies.
All channel-specific parameters such as GROUP/CHANNEL, FREQUENCY, NAME, TRANSMISSION
POWER, ENCRYPTION and MUTE LOCK can be set and adjusted manually.
The DSR 700 receiver provides frequency groups with specially calculated frequencies. In the
GROUP/CHANNEL menu you can set and synchronize a channel (frequency) manually.
Make certain that all selected channels are from the same Group within the same Pre-
set. To find clean channels we recommend using the QUICK SETUP function.
The FREQUENCY sub-menu allows frequency adjustments in 25-kHz increments.
You can enter any name (the name of a performer or instrument, etc) for each channel.
The TRANSM.POWER sub-menu lets you adjust the RF output power of the synchronized trans-
mitter.
If you turn on the encryption function, the receiver will calculate a unique key every time that you syn-
chronize the transmitter. The receiver uploads the key during the infrared synchronization process.
You cannot read out the encryption key and it is not possible to set two transmitters to the same key.
If you use a backup transmitter you must turn off the signal encryption function.
MUTE LOCK deactivates the mute button on the transmitter. The user of the synchronized transmit-
ter cannot mute the audio signal locally.
During the infrared synchronization process the receiver overwrites all previously selected transmit-
ter settings (Group/Channel, frequency, name, transmission power, encryption key, and mute lock).
To program the transmitter to the settings you selected on the receiver, start the transmitter syn-
chronization from the receiver menu and point the infrared sensor (4) on the transmitter at the
infrared emitter (8) on the receiver from a distance of 4 inches/10 cm max.