Technical Specications - Model Q-2422/SX
Model: Q-2422/SX™, 2 Channel Mixer
Power supply: AC 115/230V, 50/60Hz selectable
Dimensions: 19” W x 7” D x 2.25” H / 482x 176x 65mm
Weight: 8.5 lbs. / 3.8 kg
Crossfader: FF-Plus - Optical detecting faders start control - Low grounding impedance crossfader
Power Consumption: 5W typical, 7W w/ full headphone output
Headphone impedance: 16 Ohms
Input Sensitivity (Level/Impedance):
Line: -14dBV (200mV) 12K Ohm +/- 2dB
Microphone: -49 dBV (3.6mV / 3K Ohms +/- 3 dB
Phono: -48dBV (4mV) 47K Ohms +/- 3dB
Aux: -14 dBV (200mV) / 47K Ohms +/- 2dB
Output Sensitivity (Level/Impedance):
Rec Out (RCA): -10dBV (316mV) / 2.2K Ohms +/- 2dB
Master Out (RCA): 0dBV (1V) / 610 Ohms +/-2dB
Phones (Load+32 Ohms): -8dBV (0.4V) /33 Ohms +/-2dB
Maximum Output (Load = 47K, THD = 5%)
Rec: < 18dBV (8V)
Master (RCA): < 18dBV (8V)
Balanced (XLR): < 18dBV (8V)
Channel Balance: Within 3dB
Frequency Response:
Line: 20Hz - 20KHz, ± 1dB
Phono: 20Hz - 20KHz, ± 1.5dB (RIAA)
Aux: 20Hz - 20KHz, ± 1dB
Microphone: 20Hz - 20KHz, +1,-3dB
THD - Total Harmonic Distortion (1Khz, 0dBV Output):
Master Output (Load = 47K Ohms): Less than 0.2%
Phono (Load = 32K Ohms): Less than 0.5%
Channel Equalizer:
Bass: +12 ± 1dB, -22 ± 2 dB at 70KHz
Mid: +12 ± 1dB, -27 ± 2 dB at 1KHz
Treble: +13 ±1dB, -17 ± 2 dB at 13KHz
Microphone Equalizer:
Bass: +12 ± 1dB, -12 ± 1 dB at 100KHz
Treble: +12 ± 1dB, -12 ± 1 dB at 10KHz
NOTES:
The specifications are subject to change to any improvement by negotiations in advance.
The parts are subject to change to any improvement within the range of the specifications.