Behringer LX110 Musical Instrument Amplifier User Manual


 
14
V-AMPIRE LX110
10. APPENDIX
Operating element Function FX/AMP ADJUST
ADJUST
(Push + Hold)
ADJUST
(Tap)
UP/DOWN
TREBLE High EQ - boost/cut Filter frequency - -
BASS Bass EQ - boost/cut Filter frequency - -
COMPR Compressor - Sensitivity
Attack/
Release
--
N-GATE Noise Gate - Sensitivity
Attack/
Release
--
MASTER Output volume - - - - -
UP/DOWN Selects a preset - - - - Preset selectio
n
DELAY
Calls up delay
menu
Selects a delay
effect
Mix Feedback Delay Time -
REVERB
Calls up reverb
menu
Select a reverb
effect
Mix Decay Time - -
MODUL
Calls up
modulation
menu
Selects a
modulation
effect
Mix or Depth
(depending on
effect)
2nd parameter
(depending on
effect)
Speed
Selection of
various effect
models
FX/AMP
Selects effects
and amp models
-----
UP + DOWN
Activates the
tuner
-
Tuner input
volume
Tuner calibration
(425 - 455 Hz)
--
TREBLE + BASS
Activates the
pedal function
-----
COMPR + N-GATE
Stores the
preset
----
Selects a
memory locatio
n
DELAY + MODUL
Global input
gain
-
Controls the
input gain
--
Selects a filter
preset
TREBLE + BASS
Selects pedal
calibration menu
during power-up
DELAY + MODUL
Restores the
factory presets
during power-up
The display shows "PU" or "PL"
The display shows "CL"
Key combinations
Power-up functions
Table 10.1: Overview of functions
10. APPENDIX