Elation Professional 575E DJ Equipment User Manual


 
Design Spot 575E™
©Elation Professional® 45
Design Spot 575E™
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Focus is not located in
the default position after the reset.
Zoom Er
(Zoom motor error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Stepless Zoom is not
located in the default position after the reset.
Iris Er
(Iris error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective ( or its driving IC on the main PCB). The Iris is not located in the
default position after the reset.
Fire Wheel Er
(Fire wheel error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Fire wheel is not located
in the default position after the reset.