Ericsson LBI-39055 Music Mixer User Manual


 
LBI-39055
22
Console Privilege Lists
Each console must be sent its privilege list from the
CEC/IMC Manager as follows:
NOTE
System Manager database uploads must be
accomplished before sending console privilege
lists.
1. From the CEC/IMC Manager's "CEC/IMC MOM
Options" main menu, select the "Console
Configuration" option. This will display a
sub-menu.
2. From this sub-menu, select the "Console
Privilege List" option.
3. From the "CONSOLE PRIVILEGE LIST
UPLOAD" screen, enter the number of the console
(1 - 32).
4. Select <F7> to send the privilege list data to the
console.
Saving Database Information
At the C3 Maestro console, the following database
information is saved automatically to the PC's hard disk
drive after the last record is received. No user action is
required:
User Profiles
Hardware Configurations
The following data is not saved automatically, but on
demand or by prompt:
System Manager Upload Data
CEC/IMC Manager Upload Data
Module Set-Ups
To save upload data and module set-ups, press <F10>
on either keyboard. This will save the data to the PC's hard
disk.
SYSTEM TESTS
LOW-LEVEL TESTS
The following low-level tests verify the functionality of
the PC's ability to control the Audio Tower's audio matrix
circuitry. It also verifies the line coupling circuitry and the
speaker amplifier circuitry. Cross-point audio matrix
switches are controlled (opened and closed) using the
CTEST.EXE program. These low-level tests may be
performed before any database initialization procedures.
The tests do not represent a complete functional test of the
console.
Recommended Test Equipment
Audio Signal Generator
(600-ohm output impedance)
Handheld Multimeter
Oscilloscope
600-Ohm Resistor
Test Leads
RJ-11 Modular Plugs (terminated with test leads)
Set-Up Procedure
Verify all equipment has been interconnected in
accordance with the previous installation
instructions presented in this manual.
At the Audio Tower, temporarily disconnect the
RJ-11 plugs from the LINE A and LINE B
modular jacks on the Audio PA Board (#1).
Verify the Audio Tower and the PC are powered
up.
Start the CTEST program by typing CTEST
followed by an <Enter> at the MS-DOS prompt.
The current directory must be C:\UTIL. A
copyright message and then the CTEST screen
will appear.
Test Procedure
1. Send LINE A Input Audio to SPEAKER A
Using the audio signal generator, inject a 0 dBm
1kHz tone into the LINE A balanced input on the
Audio PA Board (#1). The balanced input is the
two outside contacts on the RJ-11 modular jack
(yellow and black wires in a modular cable).