Genz-Benz 6 Musical Instrument Amplifier User Manual


 
SIGNAL SHAPE – The SHUTTLE MAX 6.0 is equipped with 3 SIGNAL SHAPE circuits, each with a level control to
adjust the amount of level the tone shaping circuit produces.
L.F. BOOST – This lter adds low frequency peaking gain in the 35-65 Hz band range. This is especially effective when
used with a 5 string bass. The level control has a range of 0 to +7dB. This lter is unique in that it provides compound,
asymmetrical slopes critical to achieving well-controlled low frequency extension.
MID SCOOP -- Engaging this switch generates a midrange frequency cut centered at 600 Hz. The level control adjusts
the amount of cut from 0dB to –15dB.
H.F. ATTACK -- adds a peaking high frequency boost in the 2.5K – 16 KHz range. The level control has a range of 0 to
+7dB.
LED indicators are provided to visually show when each lter is engaged. Each lter Q (bandwidth) is optimized for its
particular function and is different for each lter. These functions are also foot-switchable from the 5-button footswitch.
The switches on the amplier’s faceplate must be in the out position for the footswitch to work properly.
MASTER VOLUME – The MASTER VOLUME control adjusts the overall volume of the amplier and the effects
return. Typically, best results are obtained when this control is operated between the 9:00 and 3:00 o’clock positions.
OUTPUT LIMITER – The SHUTTLE MAX 6.0 contains an internal power amplier “Soft Clip” LIMITER. This LIMITER
allows simulation of the output stage saturation of a tube power amp output stage as the amplier nears it maximum
power. The LIMITER is a compound multi-stage analog circuit, is quite graceful in nature and is particularly musical
sounding, even when driven hard.
The amber output “LIMIT” LED shows limiting action for the rst 6dB above the illumination threshold and then indi-
cates power amplier clipping as the power amplier gradually transitions into gentle clipping.
NOTE: In order to achieve full power from the amplier the LIMIT LED may be ashing regularly. If the LED is illumi-
nated constantly then the amplier output could be clipping. With our unique LIMITER circuit you may not hear drastic
“harsh” distortion but it is recommended to keep the LIMIT LED away from the “constantly on” state.
MASTER SECTION STATUS INDICATORS -
•The “POWER” light indicates that the amplier is ON and the low voltage power supplies are active.
•The red “PROTECT” LED indicates that the amp is in “PROTECT” mode. This LED may ash during power turn-on
and turn-off. This is normal. It will also illuminate during any internal fault condition. If this happens, turn the amp off
and consult a repair technician.
•The blue “SIGNAL” LED indicates that the power amplier has received signal (over several watts output) and is
performing properly.
•The Amber “LIMIT” LED indicates that the power amp has reached maximum power and/or the limiter
threshold has been crossed. Under high output conditions it is normal that this LED will light with the strongest pulses
of the signal. Driving hard beyond this point will cause the amplier to gradually begin clipping.
4