Korg SP-200 Electronic Keyboard User Manual


 
28 Chapter 5
The following table shows which data are saved with the Data Dump.
Saving data to the data filer. Here is how to save the data of the SP-200.
1 Use a MIDI cable to connect the SP-200 MIDI OUT to the MIDI IN of the data
filer.
2 Prepare the data filer to receive MIDI data.
3 On the SP-200, hold down the TRANSPOSE/FUNCTION button, and press the
VIBES/GUITAR sound selection button. The LEDs of the TRANSPOSE/FUNC-
TION and VIBES/GUITAR buttons will blink, indicating that the SP-200 is ready to
transmit the data dump.
4 Press the TOUCH button. The data dump will begin, and the sound setting data will
be transmitted to the data filer.
During a data dump operation, the SP-200 will not produce sound, and no other
function will work. When the data dump is completed, you will return to normal
playing condition.
You may cancel a data dump operation before the data dump begins, by pressing the
TRANSPOSE/FUNCTION or VIBES/GUITAR button.
Loading data from the data filer. You can load into the SP-200 data you previ-
ously saved on a data filer.
1 Use a MIDI cable to connect the MIDI IN of the SP-200 to the MIDI OUT of the
data filer.
2 On the SP-200, hold down the TRANSPOSE/FUNCTION button and press the
VIBES/GUITAR sound selection button. The LEDs of the TRANSPOSE/FUNC-
TION and VIBES/GUITAR buttons will blink, and the SP-200 will wait to receive
the data dump.
3 Set the data filer to send the sound setting data that were previously saved from the
SP-200. Please read the data filer owner’s manual for details on data transmission.
The SP-200 will receive the data.
Category Data
Single mode Reverb and chorus settings (on/off status, send level)
Layer mode Reverb and chorus settings (on/off status, send level),
balance between sounds, damper pedal on/off status
for each sound.