PAGE 16 — MULTIQUIP EM-900SDCE — OPERATION AND PARTS MANUAL — REV. #2 (09/14/07)
FUEL
1. Lift the fuel cap latch (Figure 1) located on
top of the fuel tank, then look inside the tank
and determine if the engine fuel is low . If fuel
is low, fill with
diesel fuel
(Figure 4).
EM-900SDCE MIXER — INSPECTION
ENGINE OIL
1. Remove the engine oil dipstick from its holder (Figure 5).
2. Determine if the engine oil is low (Figure 6), add correct
amount of engine oil to bring oil level to a normal safe level.
See Table 4 for recommended oil type.
See Figures 1 and 2 (Pages 11 and 12) for the location of any
control or component referenced in this manual.
Figure 4. Fuel Tank
Figure 5. Oil Filler Port/Dipstick
ZERK GREASE FITTINGS
1. Check the zerk grease fittings at each end of the mixing
drum (Figure 7). These grease fittings lubricate the dumping
mechanism. If the dumping handle is stiff or hard to move
lubricate these fittings.
Figure 6. Dipstick
Figure 7. Zerk Fittings (Bearings)
CAUTICAUTI
CAUTICAUTI
CAUTION
Handle fuel safely. Motor fuels are highly
flammable
and
can be dangerous if
mishandled. DO NOT smoke while
refueling. DO NOT attempt to refuel mixer if the engine is hot
or running.
ALWAYS
allow engine to
cool
before refueling.