Ridge Tool Company12
drum. Insert bolt, washers and nut and tighten se-
curely. Push the remainder of the pigtail into drum.
9. Push the end of the pigtail through guide tube. Install
inner drum and bearing by reversing Steps 4 and 5.
10. Place the drum assembly into the machine by fol-
lowing instructions in Step 2 of Drum Assembly In-
stallation section.
Proper Tool Selection
A good rule of thumb is to make the first pass with either
a grease cutter or blade cutter that is 2″ smaller than the
drain size. For additional passes, larger tools may be
used. However, tools should generally be at least 1″
smaller than the drain size. Use a full size blade on the
final pass.
The style of tool is determined by the nature of the job and
is left to the discretion of the operator.
Flexible leaders should be used to negotiate bends and
traps in lines.
Accessories
Only the following RIDGID products have
been designed to function with the K-6200 Drain Cleaning
Machine. Other accessories suitable for use with other
tools may become hazardous when used on the K-6200.
To prevent serious injury, use only the accessories listed
below.
Catalog No. Description
• 49032 Front Guide Hose Assembly
• 95797 Lifting Hook
• 95792 Swivel Loading Wheel Assembly
• 95802 K-6200 Drum Assy. w/
5
/
8
″ Pigtail
• 95807 K-3800 Drum Assy. w/6200 Adapters
• 95822 K-3800 to K-6200 Adapter Kit Only
• 59982 Cable Rust Inhibitor 1 Qt.
• 59987 Cable Rust Inhibitor 1 Gal.
NOTE! See page 5 for listing of cables and tools for the
K-6200. Consult a Ridge tool Catalogue for listing
of tools and cables to be used with the K-3800
drum.
K-3800 Drum Option
Installing K-3800 Drum
1. Insert rear adapter into gear box in back of drum, in-
serting “O” ring end into drive gear. “O” ring will hold
adapter in place while installing drum. (Figure 15)
Figure 15 – K-3800 Drum with K-6200 Adapters
2. Place front hex adapter on front nosepiece of guide
tube assembly and tighten wing nut.
3. Slide drum assembly into rear adapter on gear box.
4. Nest hex head front adapter onto front mounting block.
5. Attach autofeed by sliding the assembly onto the
cable. Slide assembly onto front support and align with
hex adapter. Tighten wing nuts.
Using the K-3800 Drum
1. The K-3800 drum should only be used to clean drain
lines 2″ to 4″ in diameter.
Only
1
/
2
″ diameter cable is recommended
for use in this K-3800 option. Use of smaller diameter ca-
bles may result in kinking and breakage.
2. Follow the same Operating Instructions previously
outlined when cleaning drain. To use the autofeed,
Feed knob must be turned until top bearing makes
contact with the cable. Turn one full additional turn but
do not over-tighten.