Channel Message
Program Change – Inc
Assign the program change increment function (PC
INC).
This will transmit a program change number that is one
greater than the program change number most
recently transmitted in the A-PRO’s program change
mode.
fig.editor-pcinc.eps
RPN
Assign a registered parameter number.
fig.editor-rpn.eps
Specify the following parameters.
* The range for the data entry LSB is fixed at 0–127 and
cannot be changed.
NRPN
Assign a non-registered parameter number.
fig.editor-nrpn.eps
Specify the following parameters.
* The range for the data entry LSB is fixed at 0–127 and
cannot be changed.
Item Content
MIDI Channel MIDI channel
RPN MSB RPN parameter number MSB
RPN LSB RPN parameter number LSB
MSB Min Value Lower limit of data entry MSB
MSB Max Value Upper limit of data entry MSB
Item Content
MIDI Channel MIDI channel
NRPN MSB NRPN parameter number MSB
NRPN LSB NRPN parameter number LSB
MSB Min Value Lower limit of data entry MSB
MSB Max Value Upper limit of data entry MSB