Sony SRP-X700P Musical Instrument User Manual


 
10
REMOTE PARALLEL Terminal
The REMOTE PARALLEL terminal enables the SRP-X700P to be
remotely controlled with a simple circuit connected externally to
this terminal.
Terminal shape : D-sub 25-pin, female
Recommended cable : Multi-core shielded cable for data
communication
Cable length : 50 m or less
INPUT terminal
You can set the functions of the respective terminals from the
PARALLEL INPUT FUNCTION setup box in the REMOTE
screen of the supplied SRP-X700P Manager software.
All faders and sound volume controls can be controlled from a
remote location by connecting a variable resistor as shown, in the
range of 0 to
dB.
You can perform the following operations by adding a make contact.
Input selection of LINE 4 system
Muting
Scene recall
Sound volume adjustment (Up/Down)
Controlling the AV equipment connected to the CONTROL S
terminal
Power-ON/STANDBY selection of a projector
OUTPUT terminal
The turning ON conditions of the respective pins of the OUTPUT
terminal can be set from the following.
Input selector state of LINE 4 system
Turning ON the OVER and
indicators
Turning ON the scene recall button
Generation of the Power-ON/STANDBY command of a
projector
You can select the ON conditions from the PARALLEL OUTPUT
FUNCTION setup box on the REMOTE screen of the supplied
SRP-X700P Manager software.
(D-sub 25-pin, female)
<Example of input circuit>
10 k
Curve-B variable
resistor
GND
(Nos. 1, 14 and 25)
<Example of output circuit>
GND
(Nos. 1, 14 and 25)
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Function
GND
INPUT1
INPUT2
INPUT3
INPUT4
INPUT5
INPUT6
INPUT7
INPUT8
INPUT9
INPUT10
INPUT11
INPUT12
GND
OUTPUT1
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
OUTPUT6
OUTPUT7
OUTPUT8
OUTPUT9
OUTPUT10
GND
SRP-X700P
SRP-X700P
40 mA MAX
N
SRP-X700P
24 V
MAX
0 dB
dB
Notes
Do not apply any reverse voltage across the output terminal.
Do not connect the shield cable of the REMOTE wire and the
GND wire to the terminal table or the like. It can cause
malfunction and noise.
Install the REMOTE cable away from the dimmer, motor and
others.
When the PARALLEL input terminal is used to set the projector
power to either the power-ON state or to the power-STANDBY
state, the projector power enters the power-ON state when the
PARALLEL input is set to ON. The projector power enters the
power-STANDBY state when the PARALLEL input is set to
OFF. Therefore, use an alternate type switch for power control.
Input terminal
(No. 2 to No. 13)
Output terminal
(No. 15 to No. 24)
Input terminal
(No. 2 to No. 13)
GND
(Nos.
1,
14 and 25)
How to Control the SRP-X700P from External Equipment
LED