Yamaha QY70 Recording Equipment User Manual


 
(3-4) NON-REGISTERED PARAMETER NUMBER
STATUS 1011nnnn (BnH) n = 0 ~ 15 VOICE CHANNEL NUMBER
LSB 01100010 (62H)
RPN LSB 0ppppppp
p = NRPN LSB (Refer to the table on the following page.)
MSB 01100011 (63H)
RPN MSB 0qqqqqqq
q = NRPN MSB (Refer to the table on the following page.)
DATA ENTRY MSB 00000110 (06H)
DATA VALUE 0mmmmmmm m = Data Value
First transmit an NRPN MSB and NRPN LSB to specify the parameter that is to be controlled, then use
Data Entry to set the value of the specified parameter.
NRPN D.ENTRY
MSBLSB MSB LSB PARAMETER NAME DATA RANGE
01H 08H mmH VIBRATO RATE 00H - 40H - 7FH (-64 - 0 - +63)
01H 09H mmH VIBRATO DEPTH 00H - 40H - 7FH (-64 - 0 - +63)
01H 0AH mmH VIBRATO DELAY 00H - 40H - 7FH (-64 - 0 - +63)
01H 20H mmH FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63)
01H 21H mmH FILTER RESONANCE 00H - 40H - 7FH (-64 - 0 - +63)
01H 63H mmH EG ATTACK TIME 00H - 40H - 7FH (-64 - 0 - +63)
01H 64H mmH EG DECAY TIME 00H - 40H - 7FH (-64 - 0 - +63)
01H 66H mmH EG RELEASE TIME 00H - 40H - 7FH (-64 - 0 - +63)
14H rrH mmH DRUM INST FILTER CUTOFF FREQ. 00H - 40H - 7FH (-64 - 0 - +63)
15H rrH mmH DRUM INST FILTER RESONANCE 00H - 40H - 7FH (-64 - 0 - +63)
16H rrH mmH DRUM INST AEG ATTACK RATE 00H - 40H - 7FH (-64 - 0 - +63)
17H rrH mmH DRUM INST AEG DECAY RATE 00H - 40H - 7FH (-64 - 0 - +63)
18H rrH mmH DRUM INST PITCH COARSE 00H - 40H - 7FH (-64 - 0 - +63)
19H rrH mmH DRUM INST PITCH FINE 00H - 40H - 7FH (-64 - 0 - +63)
1AH rrH mmH DRUM INST LEVEL 00H - 7FH (0 - maximum)
1CH rrH mmH DRUM INST PANPOT 00H, 01H - 40H - 7FH
(random, left - center - right)
1DH rrH mmH DRUM INST REVERB SEND LEVEL 00H - 7FH (0 - maximum)
1EH rrH mmH DRUM INST CHORUS SEND LEVEL 00H - 7FH (0 - maximum)
1FH rrH mmH DRUM INST VARIATION SEND LEVEL 00H - 7FH (0 - maximum)
MSB 14h-1Fh (for drum) are valid only if the channel is set to Drum Set Mode.
rrH : drum instrument note number
(3-5) SYSTEM REAL TIME MESSAGES
(3-5-1) ACTIVE SENSING
STATUS 11111110 (FEH)
Transmitted at intervals of approximately 200 msec.
Once this message is received, SENSING will begin. If neither STATUS nor DATA messages are received
for an interval longer that approximately 350 msec, the MIDI RECEIVE BUFFER will be cleared, and all
sounding notes and SUSTAIN SWITCH will be forced off. Also, data for each of the controls will be reset
to specific values.
(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1) UNIVERSAL NON REALTIME MESSAGE
(3-6-1-1) GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
The following controller values will be reset.
VOLUME 100
PAN Center
PROGRAM CHANGE 1 (Grandpno)
BANK SELECT MSB 0
M I D I D a t a F o r m a t
4646