Yamaha VL70-m Musical Instrument User Manual


 
28
MIDI DATA FORMAT
The Attack time, Decay time, and Release time for the Enve-
lope are controlled.
Based on a standard of 64, values will be added to or sub-
tracted from the Voice data. Depending on the Voice, the ef-
fective range may be narrower.
<RPN (Registered Parameter Number) LSB/
MSB> 64H/65H
Cntrl#
parameter Data Range
100 RPN LSB 0...127
101 RPN MSB 0...127
If the Part Parameter Rcv RPN = OFF, that Part will not re-
ceive RPN Messages.
In correspondence to the following parameters.
RPN Data-entry
LSB MSBMSB
parameter Data Range
00H 00H mmH Pitch Bend Sensitivity mm:00H-18H (0-+24)
Default:02H
01H 00H mmH Fine Tune mm:00H-40H-7FH
(-64-0-+63)
Default : 40H 00H
02H 00H mmH Coarse Tune mm:28H-40H-58H
(-24-0-+24)
Default : 40H 00H
7FH 7FH Null
5. CHANNEL MODE MESSAGES
<All Sounds Off> 78H
Cntrl#
parameter Data Range
120 ———— 0
Terminates all sounds currently sounding. However, the status
of channel messages are maintained.
<Reset All Controllers> 79H
Cntrl#
parameter Data Range
121 ———— 0
The values of the following controllers will be reset to the
defaults.
Pitch Bend Center
Channel Aftertouch 0
Modulation 0
Breath Control Max
Foot Control Max
Expression Max
Control Change 13 Center
Hold 1 Off
Portamento Off
Soft Pedal Off
RPN Null
<All Notes Off> 7BH
Cntrl#
parameter Data Range
123 ———— 0
Terminates all notes currently on. However, if Hold 1 is on,
notes will continue sounding until Hold 1 is turned off.
<Omni Off> 7CH
Cntrl#
parameter Data Range
124 ———— 0
Performs the same function as when an All Notes Off message
is received.
<Omni On> 7DH
Cntrl#
parameter Data Range
125 ———— 0
Performs the same function as when an All Notes Off message
is received. It will not activate OMNI ON.
<Mono> 7EH
Cntrl#
parameter Data Range
126 Mono 0...16
Performs the same function as when an All Sounds Off mes-
sage is received, and if the 3rd byte (mono number) is in the
range of 0 - 16, and sets the instrument to Mono Mode.
<Poly> 7FH
Cntrl#
parameter Data Range
127 ———— 0
Performs the same function as when an All Sounds Off mes-
sage is received, and sets the instrument to Poly mode.
6. CHANNEL AFTERTOUCH
Status :DnH
If the Part Parameter Rcv CHANNEL AFTER TOUCH = OFF,
that Part will not receive Channel After Touch Messages.
7. SYSTEM EXCLUSIVE MESSAGES
If the Part Parameter Rcv SYSTEM EXCLUSIVE = OFF, that
Part will not receive System Exclusive Messages.
<UNIVERSAL REALTIME MESSAGES>
1) MIDI Master Volume Receive only.
F0H, 7FH, xnH, 04H, 01H, llH, mmH, F7H
xn : n=Device Number, xn=7F : Broadcast
ll : Master Volume LSB
mm : Master Volume MSB
When received, the Volume MSB will be effective for the Sys-
tem Parameter MASTER VOLUME.