A SERVICE OF

logo

XLB-4232 DC
3-4
Upper Control Panel
The upper control panel (Figure 3-3) is mounted in the work basket. The following
controls and indicators are available on the upper control panel.
BATTERY CHARGE
INDICATOR
Figure 3-3. Upper Control Panel (DC Model)
BUCKET TILT COMPENSATOR Switch (DC Model Only)
A BUCKET TILT COMPENSATOR switch allows for slight adjustment to the level of
the work basket. Adjustment is limited to 3 degrees in either direction.
Battery Charge Indicator (DC model only)
Indicator LEDs light up to indicate the level of charge remaining in the batteries. Lighted
green LEDs indicate a good charge level. Lighted yellow LEDs indicate the need for
charging soon. Lighted red LEDs warn that the battery charge level is low; boom
operations should be halted until the batteries are recharged.
BOOM FAST/SLOW Selector Switch
The BOOM FAST/SLOW selector switch controls the speed of the selected boom
motion. Generally, the switch is set on FAST to position the boom in the general
proximity of the work area. Then, the switch is set on SLOW to fine tune the position of
the boom to get closer to the work area.
EMERGENCY STOP Pushbutton
When pressed, the EMERGENCY STOP pushbutton disconnects electrical power to the
upper and lower control panels. The EMERGENCY STOP pushbutton should only be
pressed to immediately stop all boom motion. To resume control, pull to disengage the
emergency stop switch contacts.