If contact with skin, wash with water. Prolonged contact with skin may cause irritation.
Wash with water. If clothing is wet with material, change to clean clothes and wash
affected skin. Not food quality. Do not digest. If digested, treat as dish soap. Odor from
this product may be irritating to some individuals. Discontinue use and remove to fresh
air. As with all surfactants, care must be used at all times. Rinse with plenty of water if
contact occurs. Contact CITC for further questions or copies of the MSDS at 1-888-786-
CITC or see it posted on our website at www.citcfx.com under MSDS.
4. When running the hose from the pump back to the Super Foam Dome
TM
, run the power
cord from the Super Foam Dome
TM
unit (fan) with the hose all the way back to the Super
Foam Dome
TM
making sure to keep them separated. The pump and the Super Foam
Dome
TM
will then both be plugged into the GFI. Be sure the power switch is in the OFF
position before plugging in the pump. When powering up the Super Foam Dome
TM
unit
(fan), note that the fluid will take some time to travel out before foam is produced. Never
plug the pump into a wall outlet. It must be plugged into the outlet on the GFI to insure
that the pump does not come on unless the fan is on.
5. It is important to deploy the plastic shield
enclosed in the unit. This plastic shield
prevents most of the foam or bubbles
from being sucked back inside the Super
Foam Dome
TM
fan intake. Slide the
shield half #1 onto the fan outlet, behind
the modulator (sock) and under the tip of
the molded handle located on the blower
and molded strip under machine. Slide
the shield half #2 onto the other side so
that they come together. A hole lines up
with hole from the other shield. Place the
small bolt through the hole to connect the
washer and nut. Tighten the nut securely,
locking the shield in place.
6. Make sure unit is supported and secure before supplying power and fluid to unit. Shield
should be facing the floor with the modulator (sock) pointing straight down. Never point
modulator upward as this would cause electrical damage and ruin your unit.
5.4 Operating the machine
1.
Review electrical connections: The red power switch should be OFF. The GFI should be
plugged into a properly grounded outlet. Plug both the Super Foam Dome
TM
and the
pump from the barrel into the GFI. Both units need to always come on at the same time.
o Warning: You must have both units connected through the GFI in order to use this
device. Do not attempt to use the Super Foam Dome
TM
without the GFI as shock or
shorts could occur.
Shield