A SERVICE OF

logo

June 3, 2004 Document No. 38-12009 Rev. *E 19
CY8C22x13 Final Data Sheet 3. Electrical Specifications
3.3.5 DC Analog Reference Specifications
The following tables list guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C T
A
85°C, or 3.0V to 3.6V and -40°C T
A
85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only or unless otherwise specified.
The guaranteed specifications are measured through the Analog Continuous Time PSoC blocks. The power levels for AGND refer to
the power of the Analog Continuous Time PSoC block. The power levels for RefHi and RefLo refer to the Analog Reference Control
register. The limits stated for AGND include the offset error of the AGND buffer local to the Analog Continuous Time PSoC block.
3.3.6 DC Analog PSoC Block Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40°C T
A
85°C, or 3.0V to 3.6V and -40°C T
A
85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only or unless otherwise specified.
Table 3-10. 5V DC Analog Reference Specifications
Symbol Description Min Typ Max Units
AGND = Vdd/2
a
CT Block Power = High
a. AGND tolerance includes the offsets of the local buffer in the PSoC block. Bandgap voltage is 1.3V ± 2%.
Vdd/2 - 0.043 Vdd/2 - 0.025 Vdd/2 + 0.003 V
Table 3-11. 3.3V DC Analog Reference Specifications
Symbol Description Min Typ Max Units
AGND = Vdd/2
a
CT Block Power = High
a. AGND tolerance includes the offsets of the local buffer in the PSoC block. Bandgap voltage is 1.3V ± 2%
Vdd/2 - 0.037 Vdd/2 - 0.020 Vdd/2 + 0.002 V
Table 3-12. DC Analog PSoC Block Specifications
Symbol Description Min Typ Max Units Notes
R
CT
Resistor Unit Value (Continuous Time) 12.24 k
C
SC
Capacitor Unit Value (Switch Cap) 80 fF
[+] Feedback