8Ć36 Troubleshooting
C4699Ć90000
Align
Cartridges
+
Service Mode 1 (230/250C)
(Details ' page 7-3.)
Shift
Stopping most Tests
Service-Mode 2
(Details ' page 7-4.)
Print
Quality
+
Form
Feed
+
Service Mode 1 (330/350C)
(Details ' page 7-3.)
Viewing Test Output on an HP Palmtop PC
Some of the tests in service mode 1 send test information to the plotter's serial port. To view
the information on an HP Palmtop PC, perform the procedure below.
1 Turn the plotter and Palmtop off.
2 Use HP cable number F1015Ć80002 and adapter number 5181Ć6640 to connect the
Palmtop to the plotter's serial interface port.
Both cable and adaptor are included in the HP F1021B Connectivity Pack.
3 Turn the plotter on in service mode 1.
4 Turn the Palmtop on.
5 Open the
Data Comm application on the Palmtop.
6 Press
MENU.
7 Move to the
Connect menu and press ENTER.
8 Ensure that
Settings are the same for both plotter and Palmtop.
9 Again move to the
Connect menu and press ENTER.
10 With Connect highlighted in the Connect menu, press ENTER.
11 Perform the service tests on the plotter.
To stop communication between the plotter and the Palmtop, highlight
Hangup in the
Connect menu and press ENTER.