A SERVICE OF

logo

230
250C
Media Type
Read Settings
Print Quality
Align Cartridges
Cancel
Replot
8Ć54 Troubleshooting
C4699Ć90000
Clearing the EEROM for the DesignJet 230 and 250C
If you clear the calibration parameters, you will then need to perform the plotter
calibrations. (Details ' chapter 7.) Clearing the EEROM also resets the factory
spittoon value to 0% used. Keep in mind that the value printed on the service
configuration plot may greatly underestimate the amount of ink in the spittoon.
CAUTION
Clearing Just the Benchrun and Calibration Parameters
1 Switch the plotter off.
2 While holding both the
Read Settings and Media Type keys down,
switch the plotter on.
3 Once the the LEDs begin to light up one by one, release the
Read Settings and Media Type keys.
Clearing Just the UserĆDefined Setup Parameters
1 Switch the plotter off.
2 While holding both the
Align Cartridges and Print Quality keys
down, switch the plotter on.
3 Once the the LEDs begin to light up one by one, release the
Align Cartridges and Print Quality keys.
Clearing All Parameters
1 Switch the plotter off.
2 While holding both the
Cancel and Replot keys down,
switch the plotter on.
3 Once the the LEDs begin to light up one by one, release the
Cancel and Replot keys.