A SERVICE OF

logo

C–12 ALG: Summary
File name hp 33s_user's manual_English_E_HDPM20PIE30.doc Page: 409
Printed Date : 2005/10/18 Size : 13.7 x 21.2 cm
100
8
÷ 5
8
=
?
100 ¯ 5 Ï


Integer part of result.
5A0
16
+ 10011000
2
=
?
¹
{

} 5A0
Ù


Set base 16;
HEX
annunciator on.
¹
{

}
10011000


_
Changes to base 2;
BIN
annunciator on.
Ï

...

Result in binary base.
¹
{

}

...

Result in hexadecimal
base.
¹
{

}


Restores decimal base.
Entering Statistical Two–Variable Data
In ALG mode, remember to enter an (x, y) pair in reverse order (y w x) so
that y ends up in the Y–register and X in the X–register.
1.
Press
¹ ¡ {Σ} to clear existing statistical data.
2.
Key in the y–value first and press
w.
3.
Key in the corresponding x–value and press
/.
4.
The display shows n, the number of statistical data pairs you have
accumulated.
5.
Continue entering x, y–pairs. n is updated with each entry.
Example:
Key in the x, y–values on the left, these make the corrections shown on the right:
Initial x, y Corrected x, y
20, 4 20, 5
400, 6 40, 6