A SERVICE OF

logo

Preparing for installation 55
1. Environmental specification for operating condition should be satisfied before the disk
subsystem is powered on. Maximum temperature of 32ºC should be strictly satisfied at
the air inlet portion. The recommended temperature range is 21~24ºC.
2. Nonoperating condition includes both packing and unpacking conditions unless
otherwise specified.
3. On shipping/storage condition, the product should be packed with factory packing.
4. No condensation in and around the drive should be observed under any conditions.
5. The specifications apply to all three axes.
6. See ASTM D999-86, Standard Methods for Vibration Testing of Shipping Containers.
7. See ASTM D880-86, Standard Methods of Incline Impact Test for Shipping Containers.
8. See ASTM D775-80, Standard Methods for Drop Test for Loaded Boxes.
Specification Operating
1
Nonoperating
2
Shipping and
Storage
3
Temperature (°C) 16 to 32 –10 to +43 –25 to +60
Relative humidity (%)
4
20-80 8-90 5-95
Max wet bulb (°C) 26 27 29
Temperature deviation
(°C/hour)
10 10 20
Vibration
5
0.25mm,
5-10Hz
0.05G,
10-300Hz
2.5mm,
5-10 Hz
0.5G,
10-70 Hz
0.05mm,
70-99 Hz
1.0G,
99-300 Hz
0.5, 15 min.
6
at four most severe
resonance between
5-200Hz
Shock 8G, 15ms
Horizontal:
7
incline impact:
1.22m/s
Vert ical :
8
rotational edge:
0.15m