3.3.3 PU operation mode
(Operation using the operation panel (FR-DU04))
(1) Operation at 60Hz
While the motor is running, repeat the following steps 2 and 3 to vary the speed:
(2) PU jog operation
Hold down the or key to perform operation, and release it to stop.
1) Set Pr. 15 "jog frequency" and Pr. 16 "jog acceleration/deceleration".
2) Select the PU jog operation. (Press the key to choose the operation mode and press the
key to switch to PU jog operation.)
3) Hold down the or key to perform operation.
(If the motor remains stopped, check Pr. 13 "starting frequency". The motor will not start if its setting is
lower than the starting frequency.)
Step Description Image
1
Power-on → Operation mode check
Switch power on and make sure that the operation command
indication "PU" is lit.
(If it is not lit, press the key to choose the operation mode and
press the key to switch to PU operation.)
2
Running frequency setting
Set the running frequency to 60Hz.
First, press the key to select the frequency setting mode. Then,
press the key to change the setting, and press the
key to write the frequency
3
Start
Press the or key.
The motor starts running. The monitoring mode is automatically
selected and the output frequency is displayed.
4
Stop
Press the key.
The motor is decelerated to a stop.
MODE
ON
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
MODE
SET
(or)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FWD REV
REV
FWD
(or)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
STOP
RESET
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FWD REV
MODE
FWD REV