Atlas Sound ECM-20 Recording Equipment User Manual


 
AtlasSound.com – 10 –
Specifications are subject to change without notice.
Owner’s Manual
ECM-RACEWY
ECM-20, ECM-20M, & ECM-30
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
ECM-30 Front Panel Features
1. Trigger/Status Port Pin Identification
All signals are of low voltage and current. DO NOT MISS WIRE or damage may occur.
A. (+) requires a minimum of 5–24V DC to activate the module with 5mA of current. Note: The DCV can be supplied from any
source. The EVS protection requires the ECS-6RM for operation.
B. G = Circuit Ground. Must be of the same circuit as the DCV source.
C. V = AC Voltage Status Signal. Reports the Incoming AC Mains Voltage to the ECM module back to the ECS-6RM.
D. NC = No Connection
E. D = Fault Status Signal. Reports any fault conditions of an ECM module to the ECS-6RM.
2. External Trigger/Manual On Switch
The ECM-30 has a manual override switch allowing it to be used as a local Power Conditioner and Surge Suppressor. For remote
monitoring and activation, the switch must be in the “External Trigger” position.
3. Active LED
This LED will illuminate Green when the ECM module has sensed the proper DCV to to activate the unit. Note: If the ECM-30 is
connected to the ECS-6RM and the EVS circuit has been activated, this LED will not be lit. The Channel Status LED on the
ECS-6RM will flash indicating a problem and the ECM module will not turn on until the AC Mains voltage is stable.
4. AC Fault LED
If damage to the Spike Suppression circuit occurs, this LED will illuminate Red. The module may still operate but may not be
protecting the items plugged into the AC outlets. The ECM module should be inspected and repaired by a qualified technician.
5. Incoming AC LED
This LED will illuminate Red when the ECM has incoming AC power present at the module. This LED must be On to operate.
Note: If this LED is not illuminating check the following: 1) the unit is plugged in, 2) the AC Mains Breaker feeding the AC leg to
the ECM module is Off, 3) the internal fuse has been damaged. This should only be inspected by an authorized technician.
6. AC Mains Outlet
120V 30A L5-30 Receptacle
7. AC Mains Breaker
The 120VAC 30A rated breaker will open if the combined draw of all AC outlets exceeds 30A. Note: The breaker is designed to
exceed its rating for a short period of time. If the breaker is tripped, remove the load from the ECM-30 before pushing to reset.
1 2 6
5 743