REALIGNMENT
●
Flow Chart
No. Function Choices Display Remarks
3
TX frequency
Step 2.5kHz-1MHz
STP_250
Same as RX frequency.
STP_1000
Blank ————
100.0000-
T.100.0000
550.0000MHz
4
TX Signaling
Same as RX signaling.
5
Option Signaling OFF
NONE____
Default
DTMF
DTMF____
2-TONE
2TONE___
6ID
000-
___ID___
Display when an item is selected
9999999999 (about 0.5 seconds)
12345678
Display of the current setting
(If it is 8 or more digits, scroll it.)
——987 Display when a code is input
(Input it with DTMF key.)
Blank ————
[LAMP] : Data clear
7
Busy Channel
NO
BCL_NO__
Default
Lockout
Type 1
BCL_1___
BCL_YES for K type
Type 2
BCL_2___
N/A for K type
8
Beat shift
No
SHFT_NO_
Default
Yes
SHFT_YES
9
RF Power
High Power
PWR_H___
Default
Low Power
PWR_L___
10
Wide/Narrow
Wide
WIDE____
Narrow
NARROW__
11
Scan
DELETE
SCAN_DEL
Not used for TK-260G
Delete/ADD
ADD
SCAN_ADD
Default
12
Priority
No
P.CH_NO__ Not used when (Scan)
Priority is not Fixed.
Channel
Yes
P.CH_YES_
13
Home Channel
No
H.CH_NO__
Not used when Home Channel is
Yes
H.CH_YES_
not set in Key Assignment.
14
Compander
No
COMP_NO_
Not used when Wide is
selected.
Yes
COMP_YES
15
PTT ID
OFF
P.ID_OFF
Begin of TX
P.ID_1
End of TX
P.ID_2
Both
P.ID_3
16
Begin of
000-
_BOT_ID_
Not valid if Dial ID =Disable and
TX ID
9999999999999999
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
12345678
Display of the current setting
(If it is 8 or more digits, scroll it.)
——987
Display when a code is input
(Input it with DTMF key.)
Blank
————
[LAMP] : Data clear
17
END of
000-
_EOT_ID_
Not valid if Dial ID =Disable and
TX ID
9999999999999999
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
12345678
Display of the current setting
(If it is 8 or more digits, scroll it.)
——987
Display when a code is input
(Input it with DTMF key.)
Blank ————
[LAMP] : Data clear
Self programming mode
Channel Setting Mode
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
[MON]
Channel set mode Channel selection
OFF
OFF
OFF
QT DQT N DQT I
OFF QT DQT N DQT I
Group selection
[MON]
RX frequency
RX signaling
[2]
[LAMP]
[LAMP]
[LAMP]
[LAMP]
[LAMP]
[LAMP]
[LAMP]
[LAMP]
[LAMP]
Data clear
[LAMP]
Data clear
[LAMP]
Data clear
[LAMP]
[LAMP]
[ ]
[3]
TX signaling
TX freguency
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
[2]/[3]
option signaling
ID
Scan delete/add
Busy channel lockout
RF Power High/Low
Best Shift yes/no
Wide/Narrow
Compander yes/no Not used when Wide is selected.
Not used when (Scan) Priority is not Fixed.
Not used when Home Channel is not set in key Assignment.
PTT ID
Priority channel
Home channel
Begin of TX ID
End of TX ID
[ ]
Not valid if Dial ID=Disable
and PTT ID=off, or EOT is set.
Not valid if Dial ID=Disable
and PTT ID=off, or BOT is set.