Korg Trinity ProX Musical Instrument User Manual


 
02: Stereo Limiter
49
size2
02: Stereo Limiter
This effect is a stereo limiter. You can link left and right channels, or use each channel individually.
a Envelope Select
L/R Mix, L Only, R Only, L/R
Individually
Selects from linking both channels, controlling only from
left channel, only from the right channel, or controlling
each channel individually.
P.49
b Ratio 1.0:150.0:1, Inf:1 Sets the signal compression ratio.
P.15
c Threshold [dB] 400dB
Sets the level above which the compressor is applied.
P.15
d Attack 1100 Sets the attack time.
P.16
e Release 1100 Sets the release time.
P.16
f Gain Adjust [dB] 16+24dB Sets the output gain.
P.15
g Side PEQ Insert Off, On Toggles between trigger signals EQ on/off
P.16
h
Side PEQ Cutoff [Hz] 2012.00kHz Trigger signals EQ center frequency
P.16
Q 0.510.0 Trigger signals EQ bandwidth
Gain [dB] 18.0+18.0dB Trigger signals EQ gain
i Trigger Monitor Off, On
Switches between effect output monitor and trigger signal
monitor.
P.16
j
Wet/Dry Dry, 1:9999:1, Wet Sets the balance between the effect and dry sounds.
Src NoneTempo Modulation source of effect balance
Amt 100+100 Modulation amount of effect balance
a: Envelope Select
When L/R Mix is selected for this parameter, the left and right channels are
linked to control the Limiter using the mixed signal. If L Only (or R Only) is
selected, the left and right channels are linked, and the Limiter is controlled via
only the left (or right) channel.
With L/R individually, the left and right channels control the Limiter individu-
ally.
Left
Right
Wet / Dry
Wet / Dry
Stereo In - Stereo Out
Limiter
Limiter
Envelope Select
Gain Adjust
Gain Adjust
Side PEQ
Envelope - Control
Envelope - Control
Trigger Monitor
+