Use four mounting holes on two opposite sides.
Minimum distance between module edge to PV rack is 10.236 inch (260mm).
Use four clamps on the long frame.
1 2 12
1 2 12
Use four clamps on the short frame and two
clamps at the center of long frame.
Clamping Range:
From module Edge
to 10.630 inch (270mm)
Center ± 3.937 inch (100mm)
Center ± 3.937 inch (100mm)
Use four clamps on the short frame.
This installation is allowed in the following cases:
1. Slope roof: If module is installed parallel to the
rooftop.
2. Flat roof: If installed with an additional stand
such as wind shield or deflector.
This method is not tested by IEC/UL.
Clamping Range:
From module Edge to
4.724 inch (120mm)
※ Please check that PV rack does not interfere with a micro inverter.
Mounting According to the Type of PV rack
Mounting Type Clamping Type (Long Side)
Clamping Type (Short Side)
1 2 12
1 2 12
11.811 inch
(300mm)
11.811 inch
(300mm)
Clamping Range
7.874 inch (200mm)