23
After installation of AC modules is completed, next step is to install the communication gateway for monitoring.
Before installing the gateway, adhere to the following notices:
• For reliable communication, it is recommended that the gateway is installed near the distribution panel.
• To avoid damage and failure of the gateway, do not use at temperatures outside of 32 ~ 104°F (0 ~ 40°C).
• To avoid damage of the gateway, install the gateway indoors only.
• To avoid malfunction of the gateway, be sure to use only the enclosed adapter and cables.
• To avoid risk of the electric shock, do not disassemble or expose to pressure.
• To avoid risk of the electric shock, do not bend or cut cables used to connect to the gateway.
• Do not expose to water.
• Only clean with a dry cloth.
4 EnerBox
TM
Communication Gateway
4-1 Checking Components of the Communication Gateway
1
Power Port (12V / 1A)
Powers communication gateway via AC adapter.
2
PLC IN Port
Delivers signal of AC modules to communication
gateway via AC cable.
3
LAN Port
Connects to network via LAN cable. (Green light will
turn on if connected properly.)
4
RS-485 Port
Connects to serial network via RS-485 cable.
(Administrator only)
5
Power LED (Green)
Green when AC adapter is connected properly.
6
GFDI LED (Red)
Turns on in case of ground fault in solar system.
7
PLC LED (Green / Red)
Green: AC cable is connected properly.
Red: Connection disruption.
8
Wireless LAN LED (Green / Red)
Green: Wireless communication is operating
properly.
Red: Problem with wireless communication.
9
USB Port (Charge Only)
Charge smart device via supplied USB.
10
Gateway Reset Pin
Used to reset gateway if malfunctioning.
11
Wireless LAN Reset Pin
Used to reset WAP password.
※ Default password : 87654321
1
2
3
4
5
6
7
8
9
10
11
Declaration of Conformity
Trade Name : LG
Model : LGENBOX-01
Responsible Party : LG Electronics Inc.
Address : 1000 Sylvan Ave, Englewood
Cliffs, NJ 07632, U.S.A
TEL : 201-266-2534
NOTICE
• This product contains chemicals known to the California State of to cause cancer and birth defects or other
reproductive defects. Wash hands after handling.
• EnerBox warranty void if cover removed. No serviceable parts inside. Refer servicing to qualified personnel.
• To avoid communication interference, do not connect the product to power strips, surge protectors, or surge
protector-embedded power strips. It is recommended the gateway is directly connected to a120VAC outlet.
WARNING