Meyer Sound LX-300 Music Mixer User Manual


 
LX-COS Comm/Sync
Provides a communications link to the CueStation host computer system (or the computer
hosting your custom control software), a SMPTE Time Code signal generator and receiver,
and MIDI I/O.
Ports
RS232 serial, RS422 serial, MIDI In/Out, XLR SMPTE In/Out
Pin-outs
Table 4. Nine-pin Male RS232 Serial Port (DTE)
UseNamePin
1
Receive dataRX2
Transmit dataTX3
4
Reference groundGND5
6
Ready to send (not required)RTS7
Clear to send (not required)CTS8
9
Table 5. Nine-pin Female RS422 Serial Port (DTE)
UseNamePin
1
Receive dataRX2
Transmit dataTX3
4
Reference groundGND5
6
Ready to send (not required)RTS7
Clear to send (not required)CTS8
9
Table 6. Five-pin DIN Female MIDI In
UseNamePin
1
2
3
Receive dataRD+4
Receive dataRD-5
40