Meyer Sound LX-300 Music Mixer User Manual


 
Repeated occurrence of an error indicates a fault with the associated expansion module ("DMA0" corresponds to
an Analog Audio Input module; "DMA1" to a CobraNet module).
CueStation Log Window Messages
CueStation's Log window reports a number of errors from the Matrix3 system. These can be helpful in diagnosing
the root cause of a failure. The messages relevant to booting an LX-300 are:
ExplanationError Code
No Flash program detected.M3 E1.5.0, Built on yy/mm/dd, at hh:mm:ss
DMEM memory usage exceeded.
Matrix exceeds DSP capacity.Total Dynamix points exceeded x
ADSIR_InterruptsHaveBackedUpDSP Usage has reached limit. Halting processing. Please
re-send configuration.
ADSIR_BadSampleDetectedCorrupt audio detected. Muting audio for 1 second.
Unmuting audio.
INITMAIN_HSB_Packet_ErrorHSB Packet error detected
Flash program memory errorFLASH ReadFile got wrong CRC for file x, wanted y, got
z
FLASH ReadRawFile got wrong CRC for file x, wanted
y, got z
Various FPGA programming errorsFPGA still not done after 4mSeconds waiting
FPGA Length Mis-Match
FPGA program error. Byte x, bit x TotalBits x
FPGA 'DONE' not active at end of write.
Various EtherTracks ErrorsETRX: Cannot allocate memory
ETRX: Cannot read et_boot.bin (x)
ETRX: Corrupted DualPort->HSB transfer. [0x]=0x, should
be 0x
Read Again: [0x]=0x, should be 0x
ETRX: Could not read et_linux.bin (x, 0x) Trying a second
time
ETRX: CRC failed. ET=0x Should be=0x. #P=x LAST[0x]
ETRX: # Packets not right. ET=0x Should be=0x. #P=x
LAST[0x]
45