Optimus MD-1200 Electronic Keyboard User Manual


 
43
Here is the data that can be sent and re-
ceived with this keyboard and the corre-
sponding control number.
Use the Bank Select setting to select the
MD-1200’s tone groups to be changed
by the Program Number message.
Bank 0 — 0 to 127 (General MIDI
tones)
Bank 1 — 128 to 159 (synthesized
tones)
Bank 2 — 160 to 167 (drum sets)
Bank 3 — 168 to 199 (user tones)
Just before sending a Program Change
message, send two Control Change
messages with this data to the MD-
1200:
Control Number = 0, Control Value =
<bank number>
Control Number = 32, Control Value
= 0
For example, to select tone number 190
(user tone number 22), enter:
Control Number = 0, Control Value =
3 (bank number for user tone)
Control Number = 32, Control Value
= 0
Program Change = 22 (22nd tone in
bank 3)
Note:
Channel 10 is reserved for drum
sounds only, so it is not necessary to
send bank select data when changing
tones.
RPN is used when combining multiple
control changes. RPN (100 and 101) se-
lects the parameter to control, and Data
Entry (6 and 38) sets the contents of the
parameter. On the MD-1200, RPN is
used to set pitch bend range, transpose,
and tune control from an external MIDI
device.
All Sound Off
forces all sound on the
current channel to turn off, regardless of
how the sound is being produced.
All Notes Off
turns off all note data sent
from an external device on the channel.
The notes being sustained by the pedal
continue to sound until the next pedal off
signal is received.
Reset All Controllers
initializes pitch
bend and all other control changes.
Effect
Control
Number
Bank Select 0, 32
Volume 7
Pan 10
Expression 11
Hold1 (Sustain) 64
Sostenuto 66
Soft Pedal 67
RPN (Registered Parameter
Number)
100/101
Data Entry 6/38
42-4041.fm Page 43 Tuesday, August 3, 1999 6:56 AM