Pelco KBD300A Electronic Keyboard User Manual


 
[ 28 ] Pelco Manual C527M-L (3/04)
Table D. Keyboard Functions (continued)
Function Procedure
Patterns Programming and operation varies with the receiver type.
Spectra
®
domes (before version 3.0) can use one long (1 minute) or two
short (0.5 minute) patterns. Spectra domes (version 3.0), Spectra II
domes and Esprit
®
Integrated Positioning Systems can use one long
(1.5, 3 or 6 minutes) or two short (0.75, 1.5 or 3 minutes) patterns. (Select pat-
tern lengths at the positioning system’s menu.) Spectra III
can use four
patterns of varying length (all drawing from the same block of memory, which
is almost infinite).
To program Spectra and Esprit, select a camera (1-16) ᕫᕹ, select a long
pattern by holding down PATTERN ᕫᕾ for two seconds, or select short
pattern 1 or 2 by entering 1 or 2 ᕫᕹ and holding down PATTERN ᕫᕾ for two
seconds. The monitor will indicate the programming function is active. Move
the camera position ᕫᕵ as desired for the pattern and press ACK ᕫᕺ to close
the programming function.
To run a long pattern, press PATTERN ᕫᕾ. To run a short pattern, enter 1 or 2
ᕫᕹ and press PATTERN ᕫᕾ. Move the joystick ᕫᕵ or call a preset to stop.
Direct Mode is the same as above, except:
Do not program a pattern with turbo pan on (switch 6).
To program Spectra III, enter 95, and then hold down PRESET for about 5
seconds until the main menu appears. Use the joystick to position the cursor
beside Patterns and press IRIS OPEN ᕫᕶ. Position the cursor beside Pattern
Number and press IRIS OPEN ᕫᕶ. Position the cursor beside Program Pattern
and press IRIS OPEN ᕫᕶ. Follow the directions displayed on the monitor.
To run a Spectra III pattern, press the pattern number (1-4) ᕫᕹ and then
PATTERN ᕫᕾ. Move the joystick ᕫᕵ to stop.
Sequence* Sequence steps through all 16 cameras. Camera number, camera title,
sequence status, and time/date are shown on the monitor.
Press PREV 4A to step back one camera. Hold for two seconds for a back-
ward sequence. Monitor shows B. Press during sequence to speed up. Press
during a forward sequence to reverse.
Press NEXT 4B to step forward one camera. Hold for two seconds for a
forward sequence. Monitor shows F. Press during sequence to speed up.
Press during a backward sequence to go forward.
Press HOLD 4C to hold a sequence. Monitor shows H. Press HOLD to
resume.
Manually select a camera or press CAM ᕫᕸ to turn off a sequence. Monitor
shows O.
Macro Sequence* Enter 1 or 2 ᕫᕹ and press MACRO to start a group camera sequence. Monitor
shows M. Refer to your switcher manual for macro/sequence programming.
Multiplexer Displays
*Press SHIFT . Shift key LED lights. The function keys F1 through F3 and
the auxilary keys can now be used to display the images from multiple cam-
eras on the monitor.
F1/LATCH: Zoom
F2/OFF: PIP display
F3/MOM: Quad display
AUX ON: 9-screen display
AUX OFF: 16-screen display