- 7 -
1 2 3 4 5 6 7 8
on
off
would allow for translation, personal hearing assistance or other services to be incorporated into an
application.
NOTE: The USB port may exhibit static sensitivity. If the Base Station audio shuts down after
handling, please power cycle the Base Station
Note: The HD Venue System is not compatible with any other Revolabs system and therefore
cannot be installed in the same room. The HD and Solo Wireless Microphones and Charger Bases
are not interchangeable. Only two HD Venue Systems can be used in a single area. Please
contact support@revolabs.com for design recommendations.
Configuring the Revolabs HD Venue
TM
Base Station
Each Revolabs HD Venue Base Station must be configured properly prior to use. Accurate
configuration is dependent on several variables such as:
Is Line Level or Mic Level signal required?
Refer to setting Dip Switch 3 below.
How many HD Venue Systems are being used together in close proximity?
If you have more than one Revolabs HD Venue Wireless Microphone System, refer to
setting Dip Switches 5 and 6 below. Note: It is recommended that the lowest
functioning Transmit Power be used for each system.
How large is the room?
Refer to setting Dip Switches 7 and 8 below. Note: It is recommended that the lowest
functioning Transmit Power be used for each system.
Using the Rear Panel Configuration DIP Switches
DIP
Switch
Feature
Off (Default)
On
1
Output Mixing
Individual
Outputs
Mixed Output
2
Low Pass Filter
No LPF
LPF
3
Audio Output
Level
Line Level
Mic Level
4
Mute Mode
Individual
Mutes
No Mutes