Revolabs 03-HDVENUCH Microphone User Manual


 
- 11 -
1. LED display visual status for mute, un-mute, and pairing.
2. Mute button press to mute, un-mute and pair microphone.
3. Audio jack accepts a 2.5mm plug.
4. Charging port docks to Revolabs HD Charger Bases.
5. Rubber feet non-slip, vibration absorbing pads.
6. Acoustic Cover protects delicate microphone element (non-removable).
To use the HD Omni Tabletop Microphone:
1. Remove the microphone from the Charger Base to turn on and automatically mute the mic.
(indicated by a flashing RED LED)
2. Omni Tabletop microphones can be centered on the table within 2 to 5 feet (0.6 to 1.5m) away
from people speaking and do not need to be pointing any particular direction because they pick up
sound from all directions. It is always better to be as close to the person speaking as possible,
but avoid placing the microphone where it might be blocked by equipment or paperwork. Avoid
placing microphones too close to an audio or video conference speaker to avoid echoes. Make
sure that the microphone is always placed lying on its rubber feet atop a flat surface.
3. With the microphone in position on the table, un-mute the microphone by pressing and releasing
the Mute button (confirm by a flashing GREEN LED).
4. To turn microphone off, return the microphone unit to the Charger Base or press and hold the
Mute button for ~10 seconds until the LED turns solid RED and release button.
If the microphones are placed too far from the Base Station (~65 feet or 20 meters) the connection
will be dropped (LED flashes all colors) and the microphone will mute. After 15 seconds the
microphone will beep 5 times, and will continue beeping every 30 seconds to indicating it’s out of
range.
6
2
3
1
4
5
360 º
pickup
pattern