Sennheiser SK5212-II Microphone User Manual


 
Using the bodypack transmitter
12
Doing a frequency check
The transmitter has a frequency check mode that prevents the transmitter transmitting on an
unwanted frequency after switch-on.
To change the transmission frequency, proceed as follows:
̈ Release the ON/OFF button µ.
̈ Immediately (i.e. within five seconds) press the multi-function switch ¾ (switch position
țSET) twice.
You are now in the setting mode of the “CHAN” or “TUNE” menu where you can change the
transmission frequency (see “Adjustment tips for the operating menu” on page 21).
The automatic lock mode (autolock function)
The transmitter has an autolock function (automatic lock mode) that can be activated or
deactivated via the “LOCK” menu (see page 25). When the autolock function is activated, the
lock mode is automatically activated 10 seconds after pressing the last button.
̈ When switching on the transmitter, keep the ON/
OFF button µ
pressed.
The RF signal is deactivated. The current frequency is
displayed on the LC display panel ¿.
̈ If the displayed frequency is the correct one, release the
ON/OFF button µ.
After five seconds, “RF appears on the LC display
panel and the RF signal is activated.
Prior to this, the lock mode icon
flashes several times on
the LC display panel ¿, indicating that the lock mode is
being activated and, at the same time, the display
backlighting goes off.
The autolock function can be deactivated permanently (see page 25) or temporarily (see
page 13).
¿
µ
¾
MHz
RF
MHz
RF
4