A SERVICE OF

logo

ICP-CC488 | Installation Guide | 5.0 System Functions EN | 31
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Example
If Output 2 is programmed as 291000 in Locations
443 to 448, the Master Code holder can turn on this
output by entering:
[2 5 8 0 5][AWAY][2][AWAY][AWAY]
To turn an output off from the remote codepad:
1. Enter your Master Code and press [5][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the number of the output (1 to 3) and press
[STAY].
Two beeps sound and the output turns off.
3. Repeat Step 2 to turn off another output.
4. Press [AWAY] button to exit from this function.
Two beeps sound and the STAY and AWAY
indicators are extinguished.
Example
If Output 2 is programmed as 291000 in Locations
442 to 447, the Master Code holder can turn off this
output by entering:
[2 5 8 0 5][AWAY][2][STAY][AWAY]
5.2.8 Setting the Date and Time
Use this function when the date and time must be
changed or if the system was powered down.
If the date and time is not set, the date and time fault
appears only when the Auto Arming Time is
programmed in Locations 482 to 485 (refer to Section
17.12 Auto Arming Time on page 79), or when you
enter Fault Analysis Mode by holding down [5].
To set the new date and time:
1. Enter your Master Code and press [6][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the day, month, year, hour, and minute in
DD, MM, YY, HH, MM format (where DD is
the day of the month, MM is the month of the
year, YY is the year, HH is the hour of the day,
and MM is the minute of the day) and press
[AWAY].
Use 24:00 hour format when programming the
hour of the day.
Two beeps sound and the STAY and AWAY
indicators are extinguished. If a long beep
sounds, an error occurred when you entered the
date and time.
Example
To set the date and time for 1st January 2009 at
10:30 PM, enter:
[2 5 8 0
6][AWAY][0
1 0 1 0
9 2
2
3
0][AWAY]
5.2.9 Walk Test Mode
Walk Test Mode allows you to test detection devices
to ensure that they are functioning correctly. Before
activating Walk Test Mode, isolate any zones that are
not required for testing. Refer to Section 3.11 Isolating
Zones for more information. Use Locations 383 and
384 to enable Walk Test Mode Reports (refer to
Section 15.2).
To enter Walk Test Mode:
1. Enter your Master Code and press [7][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash. The codepad beeps once per sec
when Walk Test Mode is active.
2. Unseal and seal the zones to be tested.
The codepad sounds one long beep and the horn
speaker sounds one short beep each time a zone
is sealed or unsealed.
3. Press [AWAY] to exit from this function.
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns
to the disarmed state.
5.2.10 Event Non-volatile Memory Recall Mode
This function allows you to play back the last 40
system events that occurred. Event Non-volatile
Memory Recall Mode reports all alarms and each
arming or disarming of the system and helps with
troubleshooting system faults. The events are shown
using the codepad indicators. The event memory is
not lost even with the power supply off.
To enter Event Memory Recall Mode:
Enter your Master Code and press [8][AWAY].
Three beeps sound. The events are played back by
the codepad indicators in reverse chronological
order.
Example
If the events occurred in the following order:
Table 32: Event Sequence
Sequence Event
1 System armed in AWAY Mode
2 Alarm in Zone 3
3 Alarm in Zone 4
4 System disarmed