![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/ac/6ac1f6f4-0820-4651-885f-f6b8c3ed4dd2/6ac1f6f4-0820-4651-885f-f6b8c3ed4dd2-bg75.png)
3–27
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Displaying the Status of the Save Configuration
Feature
You can use the SHOW THIS_CONTROLLER FULL command to find out if the
save configuration feature is active and which devices are being used to store the
configuration. The display includes a line that indicates status and how many devices
have copies of the configuration, as shown in the following example.
SHOW THIS_CONTROLLER FULL
Controller:
HSZ80 (C) DEC ZG07010098 SOFTWARE XXXX-0, HARDWARE 0000
NODE ID = XXXX-XXXX-XXXX-XXXX
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
CONFIGURED FOR DUAL-REDUNDANCY WITH ZG06309900
IN DUAL-REDUNDANT CONFIGURATION
DEVICE PORT SCSI ADDRESS 7
TIME: NOT SET
Host port_1:
SCSI TARGET(S) (0,1)
PREFERRED TARGET(S) (0)
TRANSFER_RATE_REQUESTED = 20MHZ
HOST FUNCTIONALITY MODE FOR ID 0 = A
HOST FUNCTIONALITY MODE FOR ID 1 = D
Host port_2:
SCSI TARGET(S) (2,3)
PREFERRED TARGET(S) (3)
TRANSFER_RATE_REQUESTED = 20MHZ
HOST FUNCTIONALITY MODE = A
COMMAND CONSOLE LUN IS TARGET 2, LUN 5