A SERVICE OF

logo

64
7.2 Storage
Store under cover away from moisture and sources of ignition. Do not overheat in storage.
The lubricant/coolant is hygroscopic; keep the container tightly closed
8 Exposure Controls / Personal Protection
Used lubricant may become contaminated with pumped product, also verify precautions and
advice against relevant product information
8.1 Personal Protection
Hand Protection PVC or Rubber Gloves
Eye Protection Chemical goggles
Respiratory Protection Respiratory protection is unnecessary, providing concentration of
vapour, mists or fumes is adequately controlled.
8.2 Occupational Exposure Limits
Ensure good ventilation.
Threshold limit Not tested
9 Physical and Chemical Properties
FORM Viscous liquid
COLOUR Blue. Colourless may be supplied to special order
ODOUR Odourless
SOLIDIFICATION POINT -40°C / -40°F approx.
FLASH POINT 177°C / 350°F approx. (COC: ISO 2592)
BOILING POINT 290°C / 554°F
SOLUBILITY IN WATER Miscible (at 20°C)
VAPOUR PRESSURE
(20°C / 68°F) <0.01 mbar
(100°C / 210°F) <1mbar
VISCOCITY 700 mPaS approx. @ 20°C / 68°F
pH 7 approx.
AUTO IGNITION TEMPERATURE 400°C / 750°F approx.
EXPLOSION LIMITS Not established
DENSITY (20°C/68°F) 1245 kg/m3 approx.
BEHAVIOUR WITH WATER AT 20°C Hygroscopic