64
7.2 Storage
• Store under cover away from moisture and sources of ignition. Do not overheat in storage.
•
The lubricant/coolant is hygroscopic; keep the container tightly closed
8 Exposure Controls / Personal Protection
Used lubricant may become contaminated with pumped product, also verify precautions and
advice against relevant product information
8.1 Personal Protection
• Hand Protection PVC or Rubber Gloves
• Eye Protection Chemical goggles
• Respiratory Protection Respiratory protection is unnecessary, providing concentration of
vapour, mists or fumes is adequately controlled.
8.2 Occupational Exposure Limits
• Ensure good ventilation.
• Threshold limit Not tested
9 Physical and Chemical Properties
FORM Viscous liquid
COLOUR Blue. Colourless may be supplied to special order
ODOUR Odourless
SOLIDIFICATION POINT -40°C / -40°F approx.
FLASH POINT 177°C / 350°F approx. (COC: ISO 2592)
BOILING POINT 290°C / 554°F
SOLUBILITY IN WATER Miscible (at 20°C)
VAPOUR PRESSURE
(20°C / 68°F) <0.01 mbar
(100°C / 210°F) <1mbar
VISCOCITY 700 mPaS approx. @ 20°C / 68°F
pH 7 approx.
AUTO IGNITION TEMPERATURE 400°C / 750°F approx.
EXPLOSION LIMITS Not established
DENSITY (20°C/68°F) 1245 kg/m3 approx.
BEHAVIOUR WITH WATER AT 20°C Hygroscopic