Troubleshooting 5‐1
Overview
The Main Menu “Diagnostic” option is used to view the diagnostic
screen.
Diagnostic Screen
At the keypad, from the Main menu the Diagnostic screens are accessed
and the Option Boards display shows what boards are installed and
recognized by the software. If the installed board is not displayed on this
screen, the connections and software versions should be checked.
If the board is installed in Slot 1, it will be shown as Option 1.
If the board is installed in Slot 2, it will be shown as Option 2.
Installed Option Boards
EV. LOG 0r MAIN
OPTION BOARDS
OPTION 1 Ana Input
OPTION 2 None
FEEDBACK None
DIAG
STOP LOCAL
Press " or A to go to the next or
previous Diagnostic screen.
Press R to return to previous
menu.
Press A to go to Status screen.
Displays Hi Resolution Analog EXB status: voltage present at each of
the Analog Inputs and Outputs.
If the EXB is installed in Slot 1, OP1 is displayed (shown).
If the EXB is installed in Slot 2, OP2 is displayed.
Display
Comments
EV. LOG 0r MAIN
HI RES INPUTS
OP1 ANA IN1 0.0V
OP1 ANA IN2 0.0V
DIAG
STOP LOCAL
Press " or A to go to the next or
previous Diagnostic screen.
Press R to return to previous menu.
Press A to go to Status screen.
Note: This screen does not appear
unless EXBHH005 is installed.
EV. LOG 0r MAIN
HI RES OUTPUTS
OP1 ANA OUT1 0.0V
OP1 ANA OUT2 0.0V
DIAG
STOP LOCAL
Press " or A to go to the next or
previous Diagnostic screen.
Press R to return to previous menu.
Press A to go to Status screen.
Note: This screen does not appear
unless EXBHH005 is installed.