Behringer MDX1400 Musical Instrument User Manual


 
33
E
DYNAMIC ENHANCER SECTION
Type Dynamically controlled frequency correction
Process variable (Off to 6)
FUNCTION SWITCHES
SC EXTERN Switches the detector section to the external SC input.
SC MON Monitoring the external SC input, disengaging the normal audio.
INTERACTIVE Enables the Interactive Knee Adaption characteristics.
CONTOUR Allows for frequency dependent detection.
AUTO Enables the automatic and program dependent setting of the
Attack-/Release times, disengaging the manual Attack-/Release
controls.
I/O METER Switches between input and output for the Level Meter.
IN/OUT Relay controlled hard-bypass.
OPERATING LEVEL Changes the internal reference level from +4 dBu to -10 dBV.
COUPLE Linking both channels for stereo operation. Channel 1 becomes
master.
INDICATORS
Gain Reduction 12 element LED display: 1/2/4/6/9/12/15/18/21/24/27/30 dB
Input/Output Level 12 element LED display: -30/-24/-18/-12/-6/0/+3/+6/+9/+12/+18 dB
Expander/Gate Threshold2 LED for under + and above -
Function switch LED indicator for each
OPTIONS
Output Transformer BEHRINGER transformer OT-1 refittable
POWER SUPPLY
Mains voltages USA/Canada ~ 120 V AC, 60 Hz
U.K./Australia ~ 240 V AC, 50 Hz
Europe ~ 230 V AC, 50 Hz
General Export Model~ 100-120 V AC, ~ 200-240 V AC, 50-60 Hz
Fuse 100-120 V AC: 250 mA (slow-blow)
200-240 V AC: 125 mA (slow-blow)
Power consumption 5 Watts
Mains connection standard IEC receptacle
PHYSICAL
Dimension 1 3/4" (44.5 mm)H * 19" (482.6 mm) * 8 1/2" (217 mm)
Net Weight 2.2 kg
Shipping Weight 3.4 kg
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be
made from time to time to existing products without prior notice. Specifications and appearance may differ from those listed or
shown.
8. SPECIFICATIONS