Compex Systems SGX3226 Electronic Keyboard User Manual


 
Appendix I Panel Views and Descriptions
76
Features
Status and Indication
5 Redundant Power
Socket
Additional Power Socket (Optional). With this RPS,
Compex SGX3226 still able to operate even Primary Power
Supply is down.
6 Reset Button By pushing the reset button once,
The switch will clear all previous temporary error
P.O.S.T. will activate self-diagnostic program to check
any error.
Switch would be re-configured with settings stored in
non-volatile flash memory.
7 Mute Button To toggle the On or Off Switch of the Alarm Buzzer
Steady Green Normal Operation
8 System Status LEDs
Steady Red POST is running Self-diagnostic after reset
or power up
Steady Green Power supply is working in normal
condition.
9 Power LED
Steady Red
Power supply is faulty.
Power supply fault occurs.
Steady Green Primary power supply is working and RPS
is in standby mode.
Steady Red Primary power supply is faulty and RPS is
in working condition.
When the primary power resume its
electrical supply, RPS LED will still
remains Steady Red unless you reboot
your switch, then RPS LED will turn to
Steady Green.
10 Redundant PS LED
Off Both primary power supply and RPS
turned off.