ETA Systems ETA-ECS6RM Recording Equipment User Manual


 
– 21 – ETAsys.com
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
ETA-ECS6RM SPECIFICATIONS
General
Type Power Sequencer Controller
Sequencer Sections 6
Relay Sections 6
Sequence Timing Unit Settings of 1, 3 or 6 Seconds
Unit Link 3
Power Supply External Wide Rage 100V–240VAC, UL Approval
Power Consumption .8W
RoHS Compliant Yes
Dimensions H 1.75" x W 19" x D 10"
Weight 7 lbs - 3.1kg
Front Panel
Lights XLR Socket to Provide 12VDC for Optional 16" Atlas Power Gooseneck
Lamp,AP-GNL18.(Qty1Included)
LED Light Switch Two Position On/Off
Activation Switch Momentary
AC Mains Voltmeter Three Digits Digital
AC Mains Current Meter Three Digits Digital
Indicators System On, External Trigger Mode, Slave Mode
Channel Selection Momentary Switches
Channel Selected Indicator Single LED Per Channel, Total Six LEDs
Activation Indicators Six Bi-Color LEDs, One For Each Channel
Rear Panel
Sequenced Activation / Status Signal Port Six Channels Interconnect port. Trigger Out and Status Signal Return, Euro /
Phoenix Type Connector
Remote Activation Trigger 5-24VDC Continuous 10 mA, Switch Contacts, Euro /
Phoenix type Connector
Sequenced Relay Contacts Six Channels, Single Relay Contact SPST Each Channel. Euro /
Phoenix Type Connector
Sequence Time Selection Setting 1,3,6 Seconds, Dip Switch Select
System Master/Slave Assignment Master
Slave Unit 1
Slave Unit 2
Dip Switch Select
System Control Loop In/Out One IN Control Port, One Loop OUT Control Port, for Slave or Master, Three
Units Can Be Linked. Connector RJ45 (Not an Ethernet Connection)
EVS Bypass Extreme Voltage Shut Off Enable / Disable, Dip Switch Assign
LED Light Socket XLR Socket to Provide 12VDC for Optional 16" Gooseneck Lamp, AP-GNL18
LED Light Switch Two Position On/Off
DC Input Jack External Power Supply, Wide Range 100V–240VAC, 20V DCV, UL Listed
ETA-ECS6RM
Electrical Control Sequencer