Paradyne 9128-II Drums User Manual


 
12
Completing Setup of the Unit From the NOC
Procedure
1. Access the remote FrameSaver unit using the dedicated management link, using
the Node IP Address that was entered (see
Physically Installing the Unit and
Setting Up for Remote Access
on page 11).
2. Configure specific frame relay options, like CIR (committed information rate), and
any other configuration options requiring input or changes from the default settings.
3. Configure each interface according to the local management interface (LMI) and
assigned line conditions supplied by the service provider.
Configuration
Network
Frame Relay
Configuration
Data Ports
Frame Relay
4. If SNMP traps are wanted, set up managers, select the desired traps, and configure
trap dial-out if desired (see
Configuring SNMP Trap Managers and Trap Dial-Out
on
page 18).
5. Set up the modem and, if trap dial-out is desired, the Call Directories (see
Setting
Up the Modem
on page 14).
6. If the unit is equipped with an ISDN DBM, set up the DBM (see
Setting Up the ISDN
DBM
on page 16).
7. S
ave the configurations.
8. Verify the entire path from the remote unit to the NOC NMS is functioning (see
Verifying the End-to-End Path
on page 20).
9. Verify that data is being received (see
Verifying That Data is Being Received
on
page 24).
10. Verify that all PVCs, including Management PVCs, are configured; and see whether
the PVC is active or not (see
Checking PVC Connections
on page 25).
11. Verify the setup for backup, if applicable (see
Verifying the ISDN Line and That Data
Can Be Passed Between DBMs
on page 26).
The FrameSaver installation is complete.