Roland HP103 Electronic Keyboard User Manual


 
41
Chapter 6. Connecting External Devices
MIDI Send Channel Settings
MIDI features sixteen MIDI channels, numbered 1–16.
Simply connecting a cable is not enough for communication
to take place. The connected devices must be set to use the
same MIDI channels. Otherwise, no sound will be produced,
and no sounds can be selected.
* The HP103 receives all channels 1–16.
If you press
the [Strings] button
in step 2 of “Making MIDI-
related settings” (p. 40), a display like the following will
appear.
fig.disp-1
Value
1–16
Power-up default setting
1
Switching Local Control on and
Off
When connecting a MIDI sequencer, set Local Control to
“OFF.”
As illustrated, information describing what has been played
on the keyboard is passed to the internal sound generator
over two different routes, (1) and (2). As a result, you hear
overlapping or intermittent sounds. To prevent this from
happening, route (1) must be severed, by setting the unit to
what is known as “Local Off.”
fig.localcont.e
Local Control ON: The keyboard and the internal sound
generator are in a linked state.
fig.localon.e
Local Control OFF: The keyboard and the internal sound
generator are in an unlinked state. No sound will be
produced by the keyboard when it is played.
fig.localoff.e
* When a Roland MT series instrument is connected, it is not
necessary to make the Local Off setting. MT units transmit
Local Off messages when their power is switched on. If you
turn on the power in the order of the HP103
MT series,
Local Off will be set automatically.
If you press
the [Variation] button
in step 2 of “Making
MIDI-related settings” (p. 40), a display like the following
will appear.
fig.disp-on
Value
On, OFF
Power-up default setting
On
Transmitting a Performance
You Recorded
If you want to transmit a performance recorded on the
HP103 to an external MIDI device or computer, turn this
setting “On.” If this is “OFF,” the data will not be
transmitted.
If you press
the [Play] button
in step 2 of “Making MIDI-
related settings” (p. 40), a display like the following will
appear.
fig.disp-Off
Value
On, OFF
Power-up default setting
OFF
If you wish to save the performance recorded on the HP103,
use the following procedure. In this situation, your external
sequencer is set its MIDI Thru feature to be OFF. For details,
refer to the owner’s manual of your MIDI sequencer.
1.
Connect a MIDI sequencer such as the MT series (p.
40).
2.
Record the performance on the HP103 (p. 30).
3.
Set this setting to “On.”
4.
Start recording with the connected MIDI sequencer.
5.
Start playback of the recorded song on the HP103.
6.
When playback ends, stop recording with the
connected MIDI sequencer.
7.
Use a connected MIDI sequencer to save the data on a
floppy disk or other media.
(1)
MIDI
MIDI
MIDI
MIDI
(2)
IN
IN
OUT
OUT
Sequencer
Memory
Sound
Generator
Each note played
is sounded twice
Thru function On
Local On
Local On
Sound is emitted
Sound Generator
Local Off
No sound produced
Sound Generator
HP103_e.book 41 ページ 2005年3月24日 木曜日 午後4時58分