Shure DFR22 Music Mixer User Manual


 
ENGLISH
9
SPECIFICATIONS
Frequency Response
20 Hz to 20 kHz ±1 dB
Dynamic Range
110 dB minimum, A-weighted, 20 Hz to 20 kHz
Sampling Rate
48 kHz
Digital-to-Analog, Analog-to-Digital Conversion
24 bit
Impedance
Input: 10 k
Output: 120
Input Clipping Level
+24 dBu minimum
Output Clipping Level
+24 dBu
+12 dBu (with 12 dB pad)
+6 dBu (with 18 dB pad)
Total Harmonic Distortion
< 0.05%, +4 dBu, 20 Hz to 20 kHz
Propagation Delay from Input to Output
<1.5 ms
Polarity
Input to output: non-inverting (inverting optional)
Operating Voltage
100–240 Vac, 50/60 Hz (auto-switching), 1 A, maximum
Maximum Power Drain
45W
Temperature Range
Operating: –7_ to 49_ C (19_ to 120_ F)
Storage: –29_ to 74_ C (–20_ to 165_ F)
Dimensions
482.6 mm x 247.7 mm x 44.4 mm (19 in. x 9.75 in. x 1.75 in.)
(See Figure 18)
Weight
2.83 kg (6.25 lbs)
Furnished Accessories
Power Cable (DFR22) 95B8389. . . . . . . . . . . . . . . . . . . . . . . .
Power Cable (DFR22E) 95C8247. . . . . . . . . . . . . . . . . . . . . . .
5-pin DIN Shure Link Cable 95B8676. . . . . . . . . . . . . . . . . . . .
Hardware Kit 90AY8100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 Block Connector Terminals, 3-pin
(for audio inputs and outputs)
2 Block Connector Terminals, 10-pin
(for control inputs and outputs)
4 Rackmount Screws and Washers
Optional Accessories
DRS10 Wallplate unit with 10-position rotary switch for preset
control
Certifications
cULus. Listed and cUL Listed to UL 6500 and CSA E60065. Au-
thorized under Verification provision of FCC Part 15 as a Class B
Digital Device.
This Class B digital apparatus complies with Canadian ICES–003.
Conforms to European Union Directives, eligible to bear CE
marking. Meets European Union Low Voltage Requirements:
Certified to EN 60065. Meets applicable tests and per-
formance criteria in European Standard EN55103 (1996) parts 1
and 2, for residential (E1) and commercial and light industrial
(E2) environments.
NOTE: EMC conformance testing is based on the use of sup-
plied and recommended cable types. The use of other cable
types may degrade EMC performance.
EMC conformance testing is based on the fact that the computer
is used for setup purposes only and disconnected during EMC
testing.
DFR22 DIMENSIONS
Figure 18