Yamaha PLG150-VL Electronic Keyboard User Manual


 
Editing VL Voice Part Parameters
28
12 Breath Mode ................................................Settings: System, BC/WX, Velocity, Touch EG
Set the control source to be used for "breath" control. This Breath Mode is the same as the one in
the VL System Parameters except for the setting, "System." When set to "System," the control
source is determined by the setting done in the VL System Parameters.
This parameter should be set to “BC/WX” when a breath controller or Yamaha WX-series Wind
MIDI Controller is being used. When set to “Velocity,” breath variation is controlled by keyboard
initial touch response. When “Touch EG” is selected breath variation is controlled by a combina-
tion of initial keyboard touch response and aftertouch pressure. Initial key velocity sets the initial
breath level, then aftertouch pressure determines the shape of the subsequent breath envelope.
127
0
127
0
127
0
127
0
A
B
Expressivity of Each Controller
The expressivity will differ depending on the selected controller.
Original Image of
Breathing
Breath Control
BC/WX
You can accomplish the breathing as you blow
the Breath controller.
Velocity
The initial attack determines the sustained breath
strength from the beginning through the end.
Touch EG
You can express the portion “A” with the velocity
and “B” with the aftertouch.
Breath Control
Breath Control
Breath Control