Zoom G1XN Music Pedal User Manual


 
10
ZOOM G1N/G1XN
11
ZOOM G1N/G1XN
Using the Tuner
Using the Tuner
•SettingtheG1N/G1XNtothebypass
condition
In play mode or rhythm mode (
g
p. 12), press both
[
W
]/[
Q
]footswitchestogether.Whenthe
indication "bP" appears on the display, release the
switches within 1 second.
•SettingtheG1N/G1XNtothemutestate
In play mode or rhythm mode (
g
p. 12), press both
[
W
]/[
Q
]footswitchestogether.Waituntilthe
indication "bP" on the display changes to "Mt" and
then release the foot switches.
The bypass or mute condition cannot be activated when
the unit is in edit mode (
g
p. 14).
Switch to bypass or mute
1
To use the tuner function of the G1N/G1XN, the built-in effects must be bypassed (temporarily
turned off) or muted (original sound and effect sound turned off).
Play the open string to tune, and adjust the pitch.
To fine-adjust the reference pitch of the G1N/G1XN
tuner, turn the [VALUE] knob in the bypass/mute
condition.
When you turn the knob, the current reference pitch
is shown for a time on the display. The default setting
is40(centerA=440Hz).
While the reference pitch is shown, turn the
[VALUE]knobtoadjustthevalueintherangefrom
35–45(centerA=435to445Hz).
When power is turned off and on again, the reference
pitch setting will be reset to 40 (center A = 440 Hz).
Press one of the [
W
]/[
Q
] foot switches.
Tune your instrument
2
Adjusting the reference pitch of the tuner
3
Return to play mode
4
BP
BP MT
BP
MT
NOTE
NOTE
A 8
Pitch is high
Pitch is correct
Pitch is low
Indication turns faster the more the pitch is off
The left side of the display shows the note
which is closest to the current pitch.
The right side of the display shows a symbol that
indicates by how much the tuning is off.
40
40
42
40
40
42
Patchchangeatbypass/mute
When you press both [
W
]/[
Q
] foot switches
together while playing your instrument, the
sound may change momentarily just before
the bypass/mute condition is activated.
This is because the G1N/G1XN switches to
the next higher or lower patch when one of
the foot switches is pressed slightly earlier.
(When you cancel the bypass/mute
condition, the original patch number will be
active again.)
This behavior is not a defect. It is due to the
very high speed at which the G1N/G1XN
responds to patch switching. To prevent the
sound change caused by the above
condition, do not produce sound with your
instrument until the bypass/mute condition
is fully established.