A SERVICE OF

logo

212 | Detectors and Accessories | Request-to-Exit
Side View
A side view of the DS150i and DS151i coverage pattern.
Technical Specifications
Electrical
Current Draw: 26 mA at 12 VDC
Voltage: 12 VAC or VDC; 24 VAC or VDC
Mechanical
Alarm Output: Two Form C relay contacts
Indicators: One activation LED
Relay Latch Time: Adjustable to 60 sec
Enclosure Dimen-
sions:
3.8 cm x 15.9 cm x 3.8 cm (1.5 in. x 6.25 in. x 1.5 in.)
Enclosure Material: High impact ABS plastic enclosure
Power Loss Default
Mode:
Programmable fail-safe or fail-secure modes.
Timer Mode: Programmable reset (accumulative) or non-reset
(counting) mode.
Mounting Location: Surface mount on wall or ceiling
Environmental
Operating Tempera-
ture:
-29°C to +49°C (-20°F to +120°F)
Radio Frequency In-
terference (RFI) Im-
munity:
No alarm or setup on critical frequencies in the range
from 26 MHz to 1000 MHz at 50 V/m.
Ordering Information
DS150i Request‑to‑exit PIR Detector
Gray enclosure. For use in request-to-exit
(REX) applications. Provides 2.4 m x 3 m
(8 ft x 10 ft) coverage.
DS150i
DS151i Request‑to‑exit PIR Detector
Black enclosure. For use in request-to-exit
(REX) applications. Provides 2.4 m x 3 m
(8 ft x 10 ft) coverage.
DS151i
Accessories
TP160 Trim Plate
A light gray trim plate used when mounting the
detector over a standard single-gang box.
TP160
TP161 Trim Plate
A black trim plate used when mounting the
sensor over a standard single-gang box.
TP161
Bosch Security Systems B.V. www.boschsecurity.com